Split core Ground Resistnace Detector Ground Earth Resistance Tester 0.01 -100ΩInstruction:
ETCR2800KB Split-core Ground Resistnace Detector, specialize for online monitoring grounding down lead connection status, circuit grounding resistance and metal circuit connection resistance. Range
:
0.010Ω~100Ω. On-line testing, non-contact measurement, grounding wire pass through the perforation of the detector, definitely not influence grounding for lightening effect and normal operation, real time on-line testing. Use by RS485 wire communication or GPRS wireless communication data transmission, realize remote online monitoring .Detector built-in sensor and circuit board, completely sealed, ensure high-accuracy, high stability and high reliability of long time on-line monitoring at field and indoors.
Product Main Function
1. On - line monitoring the earth resistance of grounding system
2. Measure Range: 0.010Ω~100Ω
3. No need to disconnect the grounding down lead and no need with auxiliary electrodes
4. Rain and dust proof, can be installed and used in outdoor
5. Network system can be built to realize real-time detection and remote monitoring
6. EX-Mark: Exia
Ⅱ
BT3Ga
7.Explosion Proof Certification: CE18.2332X
Specification:
Function
Return circuit grounding resistance on-line monitoring, metal return circuit resistance connection online monitoring, grounding condition monitoring.
CT structure
Closed loop
Power Supply
Detector
:
6VDC
~
12VDC
,
50mA Max(GPRS 12VDC 150mA Max). (Ui
:
6V
;
Ii
:
50mA
;
Ci:0μF
;
Li:0mH
;
Pi
:
0.1W)
(
User supply)
,
Instrument and safety barrier matching relation
:
Uo≤Ui
,
Io≤Ii
,
Po≤Pi
,
Co≥Ci
,
Lo≥Li
Resistance Range
0.01Ω~100Ω
Resolution
0.001Ω
Accuracy
±2%rdg±3dgt(20
℃
±5
℃,
below 70%RH)
CT Size
56mm X 26mm
Overflow Indication
test data>100Ω, system software or LCD display “OLΩ” symbol;
Connection line
1pcs ,1 meter cord(5 core wire)
Connection Identifier
Red/brown---power supply input anode;
Black--- power supply input cathode;
Blue---RS485 signal anode;
Grey---RS485 signal cathode;
White--- grounding wire shield
(power supply input cathode can connects with analog grounding by short circuit connection)
Communication Method
Wired network: RS485 communication protocol(support MODBUS)
Wireless network: RS485 or GPRS communication protocol(support MODBUS)
Network Points
Wired network: 1 ~ 250 grounding points, scalable
Wireless network: 60000 grounding points, can be expanded
Communication distance
Wired network: about 1500m,scalable
Wireless network: not limited
Alarm Indication
the detector sound-light alarm
Alarm Setting
System Software Settings
Data Display
None
Dimensions
Detector: 124mm × 118mm × 76mm
Weight
Detector: 1KG
Working Temperature And Humidity
-20
℃
~55
℃
;20%RH~90%RH
Humidors Error
Within 5%
S hift
Automatic shift
Grounding Lead Interference Current
Should be avoid
External Magnetic Field
<40A/m
External Electric Field
<1V/m
Single Measurement time
About 0.5 second
Working current
Detector: 50mA Max.(GPRS: 12VDC 150mA Max)
Explosion-proof mark
Ex ia
Ⅱ
B T3 Ga
Explosion-proof Certification
CE18.2332X.
Protection Level
IP54
Power Supply Mode
External power supply (Equipped by user)
Packing :
Package
Outer package
Carton
Inner package
None
Accessory