Insulation Resistance Tester Meter 50V 100V 250V 500V 1000V 1500V 2000V 2500V
$ 75.49
- Description
- Size Guide
Description
Overload ProtectionInsulation resistance function: AC1200V/10 seconds; voltage function: AC720V/DC1000V/10 seconds
Legal Conformity
IEC61010-1
(
CAT
Ⅲ
600V,
POLUTION degree
Ⅱ
)
IEC61557-1,2(electronic safety requirements for low voltage distribution system below AC 1000V and DC 1500V
Electromagnetic Compatibility
conforms to IEC61326-1
,
Group 1
、
Class B
Surge Protection
6kV
(as per IEC61010.1-2001)
Identification Mark
CE
Quality Standard
develops , designs and manufactures as per ISO 9001
General Feature
Display Screen
digit: displays in 2000 digits;
white backlight
Operation Temperature and Moisture Range
0
~
40
ºC, relative moisture
≤
85
%(no condensation)
Storage Temperature and Moisture Range
-20
ºC
~
60
ºC
,
relative moisture
≤
90
%( no condensation)
Accuracy Required Temperature and Moisture Range
23±5ºC, relative moisture
≤
75
%( no condensation)
Ambient Condition for Operation
Indoor, outdoor operation
(
no waterproof
),
at an altitude of 0
~
2,000 meter
Stored Data
100 groups
Indicator for Over-range
OL
Battery
Type
eight
1.5V
Alkaline (LR6) batteries
Low Battery
displays battery mark
Automatic Power-off
The default value is 5 minutes if no operation , and adjustable.
Closed – case Calibration
no internal adjustments needed
Measurement
175
(
L
)
×110
(
W
)
×70
(
D
)
mm
Weight
about 500g
Calibration Period
One year
Measurement Range and Accuracy
Error limits are given as:
±
( [ % of reading ] + [ number of least significant digits ] ), warranty for one year.
(Note: “number of least significant digits” means the digits increased or decreased in least significant digits)
Ambient temperature: 23±5ºC ; Ambient moisture: 45
~
75%RH
Insulation Resistance Measurement
(
RISO
)
Rated voltage
Measurement range
Open-circuit voltage
Rated measured current
Accuracy
50V
0
~
1.999MΩ
DC 50V
+10% , -10%
1mA nominal value
40KΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
100V
0
~
1.999MΩ
DC 100V
+10% , -10%
1mA nominal value
100KΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
200
~
500MΩ
250V
0
~
1.999MΩ
DC 250V
+10% , -10%
1mA nominal value
250KΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
200
~
1999MΩ
500V
0
~
1.999MΩ
DC 500V
+20% , -0%
1mA nominal value
500KΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
200
~
1999MΩ
2.00
~
5.00GΩ
1000V
0
~
1.999MΩ
DC 1000V
+20% , -0%
1mA nominal value
1MΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
200
~
1999MΩ
2.00
~
9.99GΩ
1500V
0
~
1.999MΩ
DC 1500V
+20% , -0%
1mA nominal value
1.5MΩ load
5
%
+3
2.00
~
19.99MΩ
20.0
~
199.9MΩ
200
~
1999MΩ
2.00
~
19.99GΩ
2000V
0
~
19.99MΩ
DC 2000V
+20% , -0%
1mA nominal value
2MΩ load
5
%
+3
20.0
~
199.9MΩ
200
~
1999MΩ
2.00
~
19.99GΩ
20.0
~
50.0GΩ
2500V
0
~
19.99MΩ
DC 2500V
+20% , -0%
1mA nominal value 2.5MΩ load
5
%
+3
20.0
~
199.9MΩ
200
~
1999MΩ
2.00
~
19.99GΩ
20.0
~
99.9GΩ
l
Short circuit measurement current of insulation measurement: 1.5 mA nominal value
l
Automatic discharge time of insulation measurement: when the capacitance C = 1μF or lower, discharge time <1 second.
l
Alive circuit detection of insulation measurement: before the measurement’s initialization, the Instrument warns and prohibits measurement if terminal voltage is higher than 30v.
l
Maximum capacitive load of insulation measurement: available for any operation when the value is below 1μF.
Voltage Monitoring Display (insulation resistance range)
Voltage range
Measurement range
Accuracy
2500V
0
~
2500V
2%+5
AC/DC Voltage Measurement
Measurement function
D/C voltage
A/C voltage
Measurement range
0
~
±1000V
30
~
750V
(
50/60Hz
)
Resolution ratio
1V
Accuracy
3%+5
l
Output impedance: 10MΩ.
l
Measurement speed rate: about 2 times / s