    ETCR3000B
    Earth Resistance Soil Resistivity Tester
    Introduction:
    ETCR3000B Earth Resistance Soil Resistivity Tester is specially designed and manufactured for measuring earth resistance, soil resistivity, earth voltage, AC voltage. Adopting the latest digital and micro-processing technology, precise 4-pole, 3-pole and simple 2-pole method for earth resistance measurement, importing FFT and AFC technology, with a unique function of anti-interference capability and the ability to adapt to the environment, consistency of repeat testing, to ensure high precision, high stability and reliability for prolonged measure, which is widely used in electric power, telecommunications, meteorology, oil field, construction, lightning protection, industrial electrical equipment and other earth resistance, soil resistivity, earth voltage, AC voltage measurement.
    ETCR3000B Earth Resistance Soil Resistivity Tester is composed of host machine, monitoring software, testing wires, auxiliary ground pillars, communication wires and others. The large LCD display of host machine is with blue backlight and bar graph indicating that can be seen clearly. At the same time it can store 300 sets of data, fulfilling historical inquiry and online real-time monitoring through monitoring software, dynamic display, alarm indicator, and with the functions like historical data access, reading, preservation, report forms, printing and so on.
    Technical Specifications:
    1. Base Conditions and Working Conditions
    Influence Quantity
    Base Condition
    Working Conditions
    Remark
    Ambient Temp
    23
    ℃±
    1

    -10

    -40

    ----
    Ambient Humidity
    40%-60%

    80%
    ----
    Working Voltage
    9V±0.1V
    9V±1.5V
    rC

    rP
    Auxiliary Earth Resistance

    100
    Ω

    30k
    Ω
    ----
    Interference Voltage
    no

    20V
    ----
    Interference Current
    no

    2A
    Electrode Distance when measuring R
    a

    5d
    a

    5d
    ----
    Electrode Distance when measuring ρ
    a

    20h
    a

    20h
    ----
    Function
    Measurement of 2/3/4-pole earth resistance, soil resistivity, earth voltage, AC voltage
    Power Supply
    DC 9V(Zi-Mn dry battery R14S 1.5V 6 PCS, continuous standby for 300 hours )
    Measurement Range
    Earth Resistance: 0.00Ω-30.00kΩ
    Soil Resistivity: 0.00Ωm-9000kΩm
    Measuring Mode
    Precise 4-pole measurement, 3-pole measurement, simple 2-pole measurement
    Measuring Method
    Earth Resistance: rated current change-pole method, measurement current 20mA Max
    Soil Resistivity: 4-pole measurement (Wenner method)
    Earth Voltage: average rectification(between P(S)-ES)
    Test Frequency
    128Hz/111Hz/105Hz/94Hz(AFC)
    Short-circuit Test Current
    AC 20mA max
    Open-circuit Test Current
    AC 40V max
    Test Voltage Wave
    Sine wave
    Electrode Distance Range
    Can be set 1m-100m
    Shift
    Earth Resistance: 0.00Ω-30.00kΩ, automatic shift
    Soil Resistivity: 0.00Ωm-9000kΩm, automatic shift
    Backlight
    Blue screen backlight, suitable for dim places
    Display Mode
    4-digital super-large LCD display, blue screen backlight
    Measuring Indicator
    During measurement, LED flash indicator, LCD count down display, progress bar indicator
    LCD Frame Dimension
    128mm×75mm
    LCD Window Dimension
    124mm×67mm
    Dimension
    L×W×H: 215mm×190mm×95mm
    Standard Test Wire
    4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
    Simple Test Wire
    2 wires: each for red 1.6m and black 1.6m
    Auxiliary Earthing Rod
    4 rods: Φ10mm×150mm
    Measuring Rate
    Earth voltage: about 3 times/second
    Earth resistance, soil resistivity: about 5 seconds/time
    Measuring Times
    Over 5000 times (Short-circuit test, interval time should be at least 30 seconds)
    Line Voltage
    below AC 600V
    RS232 Interface
    Possess RS232 interface, software supervision, storage data can be uploaded to computer, saved or printed.
    Communication Wire
    One piece of RS232 communication wire, with length 1.5m
    Data Storage
    300 sets, “MEM” icon storage indicator, flash display “FULL” icon to indicate storage is full
    Data Hold
    Data hold function: “HOLD” icon display
    Data Access
    Data read function: “READ” icon display
    Overflow Display
    Exceeding measuring range overflow function: “OL” icon display
    Interference Test
    Recognize interference signal automatically, “NOISE” icon display when interference voltage exceed 5V
    Auxiliary Earthing Test
    Can measure auxiliary earth resistance, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
    Alarm Function
    When measuring value exceeds alarm setting value, there is “Toot-toot-toot” alarm hint
    Battery Voltage
    When battery voltage decreases to about 7.5V, battery voltage low icon will display, reminding to replace battery.
    Power Consumption
    Standby: about 20mA (Backlight shut off)
    Boot and with backlight: about 45mA (25mA without backlight)
    Measurement: about 100mA (Backlight shut off)
    Weight
    Total weight: 4.5kg (including package)
    Tester: 1443g (including battery)
    Tesing wires: 1560g
    Auxiliary earthing rods: 935g (4pcs)
    Working Temperature & Humidity
    -10

    -40

    , below 80%rh
    Storage temperature & humidity
    -20

    -60

    , below 70%rh
    Overload Protection
    Measuring earth resistance: between each interfaces of C(H)-E

    P(S)-ES,AC 280V/3 seconds
    Insulation Resistance
    Over 20MΩ (between circuit and enclosure it is 500V)
    Withstanding Voltage
    AC 3700V/rms (Between circuit and enclosure)
    Electromagnetic Features
    IEC61326(EMC)
    Protection Type
    IEC61010-1 (CAT

    300V

    CAT IV 150V

    Pollution 2), IEC61010-031, IEC61557-1 (Earth resistance), IEC61557-5 (Soil resistivity), JJG 366-2004
    2. General Specification
    3. Intrinsic error and performance indicators under base conditions
    Category
    Measurement Range
    Intrinsic Error
    Resolution
    Earth Resistance
    0.00Ω-30.00Ω
    ±2%rdg±3dgt
    0.01Ω
    30.0Ω-300.0Ω
    ±2%rdg±3dgt
    0.1Ω
    (R)
    300Ω-3000Ω
    ±2%rdg±3dgt

    3.00kΩ-30.00kΩ
    ±4%rdg±3dgt
    10Ω
    Soil Resistivity
    0.00Ωm-99.99Ωm
    According to the precision of R
    0.01Ωm
    (ρ)
    100.0Ωm-999.9Ωm
    (ρ=2πaR
    0.1Ωm
    1000Ωm-9999Ωm
    1Ωm
    10.00kΩm-99.99kΩm
    a:1 m-100m,
    10Ωm
    100.0kΩm-999.9kΩm
    100Ωm
    1000kΩm-9000kΩm
    π=3.14)
    1kΩm
    Earth Voltage
    AC 0.0-600V
    ±2%rdg±3dgt
    0.1V
    Tester
    1 PC
    Tester Bag
    1 PC
    Auxiliary Earthing Rod
    4 PCS
    Standard testing Wire
    4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
    Simple testing Wire
    2 wires: each for red 1.6m and black 1.6m
    Zinc-manganese Dry Battery
    6 PCS (R14S 1.5V)
    Monitoring Software Disk
    1 Copy
    RS232 Communication Cable
    1 PC
    Manual/Warranty Card/Qualification Certificate
    1 Copy
    Accessories

    Shipping Policy
    We will send out the item within 2-3 days through DHL/EMS/FEDEX /UPS/SPEEDPAK/CHINA POST to the below countries:
    Belgium, Netherlands, Luxembourg, Italy, Germany, France, United Kingdom, San Marino;
    Austria ,Denmark ,Finland ,Greece ,Ireland ,GUERNSEY ,JERSEY ,Norway ,
    Portugal , spain , Sweden , Switzerland;
    Bulgaria,Cyprus,Estonia,Latvia,Lithuania,Malta,slovakia,slovenia;
    Czech Republic, Hungary, Poland, Romania,.
    Australia ,New Zealand ,Korea South, Malaysia, Thailand, Philippines ,Singapore , Bruniei ,Taiwan , Macau, Indonesia,
    USA, Canada
    We will send tracking number to your eBay email within 1 day after sending out your item
    We will mark the item at the very low value, so that you do not need to pay for the tax or pay a little tax.
    Payment policy:
    We accept Paypal only.
    Payments must be finished within 5 working days after bid, otherwise, Unpaid Item dispute will be reported to eBay.
    Refund &Return policy
    We take all the responsibility during delivery. If you do not receive your item, we will refund you the full money or send you a new item according to your request.
    We can accept the return item within 60 days after the buyer receives it. Once we receive the return item, then we will refund you full money.
    Feedback Policy
    We will very appreciate you give us positive feedback
    ASAP.  If the item you got in any problem, PLS don’t hesitates to contact us.  We will do our best to help solve the problem
    Powered by SoldEazy