-40%

Double Clamp Ground Earth Resistance Tester Soil Resistivity Detector RS232

$ 361.15

Availability: 100 in stock
  • Country/Region of Manufacture: China
  • Features: RS232 Interface
  • MPN: e4566578
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Max Accuracy: ±2%rdg±3dgt
  • Meter Dimension: 215mm(L)×190mm(W)×95mm(H)
  • Weight: 1653g
  • Restocking Fee: No
  • data Storage: 2000 groups
  • Test Voltage Wave: Sine wave
  • Item must be returned within: 30 Days
  • Clamp Caliber: Φ68mm
  • Resolution: Resistance:0.01Ω
  • Brand: VTSYIQI
  • LCD Size: 124mm x 67mm(with backlight)
  • Refund will be given as: Money back or replacement (buyer's choice)
  • warranty: 1 year
  • Condition: New

    Description

    Double Clamp Ground Earth Resistance Tester Soil Resistivity Detector RS232
    Instuction:
    ETCR3200 Double Clamp Earth Resistance Tester, through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of  high precision, high stability and reliability.
    ETCR3200 Double Clamp Multi-function Grounding Resistance Tester is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.
    Product Characteristics
    1

    2/3/4-wire method measure earth resistance,Range

    0.00Ω

    30.00kΩ
    2

    Selection method meausre earth resistance, Range: 0.00Ω

    3000Ω
    3

    Doule clamp method measure earth resistance,Range: 0.01~100Ω
    4

    Soil resistivity measurement, Range

    0.00Ωm

    9000kΩm
    5

    Earth voltage measurement,Range

    AC 0

    600V
    6

    AC current measurement, Range: 0.01mA

    600A
    7

    Data storage: 2000 sets
    8

    Alarm function: audible and visual alarm
    9

    CT size: Φ68mm
    Specifciation:
    Power Supply
    DC 9V Alkaline dry cell LR14 1.5V*6PCS, continues standby 300 hours
    LCD Size
    124mm x 67mm(with backlight)
    Range
    Selection measurement method

    0.01Ω - 3000Ω
    Double clamp measurement method

    0.01Ω - 100Ω
    2/3/4 pole measurement method

    0.01Ω - 30.00kΩ
    Soil Resistivity

    0.01Ωm - 9000KΩ
    DC Resistance

    0.01Ω - 30.00kΩ
    Earth Voltage:0.1V -100.0V
    AC Current:0.01mA -600A
    Resolution
    Resistance:0.01Ω
    Soil Resistivity

    0.01Ωm
    Current:0.01mA
    Voltage:0.1V
    Max Accuracy
    ±2%rdg±3dgt
    Data Storage
    2000 groups
    Data Upload
    RS232 interface, storage data can be uploaded to computer, saved or printed.
    Automatic Shut Down
    Automatically shut down after 15 minutes start up
    Power Consumption
    Turn on the backlight

    45mA Max
    Turn off the backlight : 25mA Max
    Measurement: 100mA Max(Backlight shut off)
    Working Temperature & Humidity
    -10

    -40

    , below 80%rh
    Storage temperature & humidity
    -20

    -60

    , below 70%rh
    Clamp Caliber
    Φ68mm
    Measuring Method
    2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max
    Selection measurement method: Change-pole method, measurement current 20mA Max
    Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max
    Soil Resistivity: 4-pole measurement (Wenner method)
    AC current: Mutual inductance method(clamp)
    Earth Voltage: Average rectification(between P(S)-ES)
    Test Frequency
    128Hz/111Hz/105Hz/94Hz(AFC)
    Data Model
    Average value

    maximum

    minimum value
    line resistance check
    Automatic calibration
    Measuring Rate
    AC current: about 0.5 times/second
    Earth Voltage: about 0.5 times/second
    Earth resistance

    soil resistivity: about 5 seconds/time
    Measuring Times
    Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
    Short-circuit Test Current
    AC 20mA max
    Open-circuit Test Voltage
    AC 40V max
    Test Voltage Wave
    Sine wave
    Electrode Distance Range
    1m-100m
    Line Voltage
    Measurement below AC 600V
    Data Hold
    Data hold function: “HOLD” symbol display
    Data Access
    Data read function: “READ” symbol display
    Overflow Display
    Exceed measuring range overflow function: “OL” symbol display
    Auxiliary Grounding Test
    With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
    Interference Test
    Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
    Alarm Function
    Measuring value exceeds alarm setting value, will "Toot-toot-toot" alarm hint
    Battery Voltage
    While battery voltage decreases to around 7.5V, will display battery voltage low symbol“     ”, and reminding to replace the battery
    Overload Protection
    Measure earth resistance: between each interfaces of E-P

    E-E- C,AC 280V/3 seconds
    Insulation Resistance
    Over 20MΩ(between circuit and outside shell is 500V)
    Withstand Voltage
    AC 3700V/rms. (Between circuit and outside shell)
    Electromagnetic Features
    IEC61010- 4-3,Wireless frequency electromagnetic field ≤1 V/m
    Protection Type
    IEC61010-1(CAT

    300V

    CAT IV 150V

    Pollution 2);
    IEC61010-031;
    IEC61557-1(Earth resistance);
    IEC61557-5(Soil resistivity);
    JJG 366-2004(Grounding resistance meter)
    Weight
    1653g
    Meter Dimension
    215mm(L)×190mm(W)×95mm(H)
    Packing :
    Package
    Outer package
    Carton
    Inner package
    Aluminum case
    Accessory
    Meter
    1 PCS
    Current clamp
    2 PCS
    Aluminum case
    1 PCS
    Auxiliary grounding rod

    10x150mm

    4 PCS
    Test cable yellow 10 meters
    1 PCS
    Test cable green 10 meters
    1 PCS
    Test cable red 20 meters
    1 PCS
    Test cable black 20 meters
    1 PCS
    Test cable black1.6 meters
    1 PCS
    Test cable red 1.6 meters
    1 PCS
    RS232 communication cable
    1 PCS
    CD
    1 PCS
    Manual
    1 PCS
    Certificate
    1 PCS
    Warranty Card
    1 PCS