Double Clamp Ground Earth Resistance Tester Soil Resistivity Detector RS232Instuction:
ETCR3200 Double Clamp Earth Resistance Tester, through a variety of methods measuring earth resistance (range: 0.01Ω ~ 30.00 kΩ), soil resistivity (range: 0.01Ωm ~ 9000kΩm), earth voltage (range: 0.1 V ~ 100.0 V), grounding lead leakage current, AC current (range: 0.01mA ~ 600A); The tester adopts the precision 4-wire method, 3-wire method, simple 2-wire method, selection method and double-clamp method to measure grounding resistance. Large caliber current clamp design, can measure the grounding system which using large grounding down lead.It can flexibly and accurately measure arbitrary grounding resistance values of single point and mesh grounding and other complex grounding conditions. When measuring parallel grounding, it is unnecessary to disconnect any parallel grounding electrode to maximize the convenience of measurement. Import FFT (fast Fourier transform) technology, AFC (automatic frequency control) technology, ensure the measurement of high precision, high stability and reliability.
ETCR3200 Double Clamp Multi-function Grounding Resistance Tester is composed of host machine, current clamp, monitoring software, test wires, auxiliary ground rod and communication cable. Host machine with large LCD display, white backlight, bar chart indication, clear at a glance. It can store 2000 sets of data at the same time, through the monitoring software to relize historical access and online real-time monitoring functions, dynamic display, alarm indication and auto shut down, with historical data reading, accessing, saving, reporting, printing and other functions.
Product Characteristics
1
:
2/3/4-wire method measure earth resistance,Range
:
0.00Ω
~
30.00kΩ
2
:
Selection method meausre earth resistance, Range: 0.00Ω
~
3000Ω
3
:
Doule clamp method measure earth resistance,Range: 0.01~100Ω
4
:
Soil resistivity measurement, Range
:
0.00Ωm
~
9000kΩm
5
:
Earth voltage measurement,Range
:
AC 0
~
600V
6
:
AC current measurement, Range: 0.01mA
~
600A
7
:
Data storage: 2000 sets
8
:
Alarm function: audible and visual alarm
9
:
CT size: Φ68mm
Specifciation:
Power Supply
DC 9V Alkaline dry cell LR14 1.5V*6PCS, continues standby 300 hours
LCD Size
124mm x 67mm(with backlight)
Range
Selection measurement method
:
0.01Ω - 3000Ω
Double clamp measurement method
:
0.01Ω - 100Ω
2/3/4 pole measurement method
:
0.01Ω - 30.00kΩ
Soil Resistivity
:
0.01Ωm - 9000KΩ
DC Resistance
:
0.01Ω - 30.00kΩ
Earth Voltage:0.1V -100.0V
AC Current:0.01mA -600A
Resolution
Resistance:0.01Ω
Soil Resistivity
:
0.01Ωm
Current:0.01mA
Voltage:0.1V
Max Accuracy
±2%rdg±3dgt
Data Storage
2000 groups
Data Upload
RS232 interface, storage data can be uploaded to computer, saved or printed.
Automatic Shut Down
Automatically shut down after 15 minutes start up
Power Consumption
Turn on the backlight
:
45mA Max
Turn off the backlight : 25mA Max
Measurement: 100mA Max(Backlight shut off)
Working Temperature & Humidity
-10
℃
-40
℃
, below 80%rh
Storage temperature & humidity
-20
℃
-60
℃
, below 70%rh
Clamp Caliber
Φ68mm
Measuring Method
2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max
Selection measurement method: Change-pole method, measurement current 20mA Max
Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
AC current: Mutual inductance method(clamp)
Earth Voltage: Average rectification(between P(S)-ES)
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Data Model
Average value
,
maximum
,
minimum value
line resistance check
Automatic calibration
Measuring Rate
AC current: about 0.5 times/second
Earth Voltage: about 0.5 times/second
Earth resistance
,
soil resistivity: about 5 seconds/time
Measuring Times
Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Voltage
AC 40V max
Test Voltage Wave
Sine wave
Electrode Distance Range
1m-100m
Line Voltage
Measurement below AC 600V
Data Hold
Data hold function: “HOLD” symbol display
Data Access
Data read function: “READ” symbol display
Overflow Display
Exceed measuring range overflow function: “OL” symbol display
Auxiliary Grounding Test
With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Interference Test
Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Alarm Function
Measuring value exceeds alarm setting value, will "Toot-toot-toot" alarm hint
Battery Voltage
While battery voltage decreases to around 7.5V, will display battery voltage low symbol“ ”, and reminding to replace the battery
Overload Protection
Measure earth resistance: between each interfaces of E-P
、
E-E- C,AC 280V/3 seconds
Insulation Resistance
Over 20MΩ(between circuit and outside shell is 500V)
Withstand Voltage
AC 3700V/rms. (Between circuit and outside shell)
Electromagnetic Features
IEC61010- 4-3,Wireless frequency electromagnetic field ≤1 V/m
Protection Type
IEC61010-1(CAT
Ⅲ
300V
、
CAT IV 150V
、
Pollution 2);
IEC61010-031;
IEC61557-1(Earth resistance);
IEC61557-5(Soil resistivity);
JJG 366-2004(Grounding resistance meter)
Weight
1653g
Meter Dimension
215mm(L)×190mm(W)×95mm(H)
Packing :
Package
Outer package
Carton
Inner package
Aluminum case
Accessory
Meter
1 PCS
Current clamp
2 PCS
Aluminum case
1 PCS
Auxiliary grounding rod
(
10x150mm
)
4 PCS
Test cable yellow 10 meters
1 PCS
Test cable green 10 meters
1 PCS
Test cable red 20 meters
1 PCS
Test cable black 20 meters
1 PCS
Test cable black1.6 meters
1 PCS
Test cable red 1.6 meters
1 PCS
RS232 communication cable
1 PCS
CD
1 PCS
Manual
1 PCS
Certificate
1 PCS
Warranty Card
1 PCS