Double Clamp Earth Resistance Tester Multi-function Soil Resistivity MeasurementETCR3200C Double Clamp Multi-function Grounding Resistance Tester is specially designed and manufactured for on-site measurement of grounding resistance, soil resistivity, grounding voltage, grounding line leakage current, AC current and DC resistance. Apply digital processing technology, precision 4-wire method, 3-wire method and simple 2-wire method, selection method, double-clamp method to measure grounding resistance; Large caliber clamp design can measure the grounding system which using large grounding down lead, and can flexibly and accurately measure any grounding resistance value of various complex grounding conditions such as single point and mesh grounding. It is not necessary to disconnect any parallel grounding pole to measurement, maximize the convenience of measurement. Import FFT (Fast Fourier Transform) technology, AFC (Automatic Frequency Control) technology, with unique anti-interference ability and environmental adaptability, high repeated test consistency, ensuring high precision, high stability and high reliability for long-term measurement. The tester case is made of waterproof protection box, anti-collision, anti-drop, waterproof (protection grade IP65), strong and durable, and also equipped with a large-capacity rechargeable lithium battery pack, especially suitable for outdoor construction. Widely used in power, telecommunications, meteorology, oil fields, construction, lightning protection and industrial electrical equipment, such as grounding resistance, soil resistivity, grounding voltage, alternating current, leakage current measurement.
Product Characteristics
1
:
2/3/4-wire method measure earth resistance,Range
:
0.00Ω
~
30.00kΩ
2
:
Selection method meausre earth resistance, Range: 0.00Ω
~
3000Ω
3
:
Doule clamp method measure earth resistance,Range: 0.01~100Ω
4
:
Soil resistivity measurement, Range
:
0.00Ωm
~
9000kΩm
5
:
Earth voltage measurement,Range
:
AC 0
~
600V
6
:
AC current measurement, Range: 0.01mA
~
600A
7
:
Data storage: 2000 sets
8
:
Alarm function: audible and visual alarm
9
:
CT size: Φ68mm
10
:
Waterproof case + Super large capacity lithium battery
Technical Specifications
Function
Measure grounding resistance, soil resistivity; DC resistance, earth voltage, AC current , leakage current
Power Supply
DC 8.4V (rechargeable battery, continues standby 300 hours)
Backlight
Controllable screen backlight, suitable for dim places
Measuring Mode
Precise4-pole measurement, 3-pole measurement, simple 2-pole measurement, selection method, double clamp method measure grounding resistance
Measuring Method
2/3/4 pole measurement method: Change-pole method, measurement current 20mA Max
Selection measurement method: Change-pole method, measurement current 20mA Max
Double clamp measurement method: Non-connect mutual inductance method, measurement current 1mA Max
Soil Resistivity: 4-pole measurement (Wenner method)
DC resistance: Change-pole method
AC current: Mutual inductance method(clamp)
Earth Voltage: Average rectification(between P(S)-ES)
Test Voltage Wave
Sine wave
Test Frequency
128Hz/111Hz/105Hz/94Hz(AFC)
Short-circuit Test Current
AC 20mA max
Open-circuit Test Current
AC 40V max
Electrode Distance Range
1m-100m
Display Mode
4-digital large LCD display, with screen backlight
Measuring Indicator
During measurement, LED flash indicator, LCD countdown display
LCD Frame Dimension
128mm×75mm
LCD display area
124mm×67mm
Instrument Dimension
280mm(L)×260mm(W)×160mm(H)
CT Size
185mm(L)X115mm(W)X43mm(H)
Test Wire
4 wires: each for red 20m, black 20m, yellow 10m, and green 10m
Simple Test Wire
2 wires: each for red 1.6m and black 1.6m
Auxiliary Grounding Rod
4PCS: Φ10mm×150mm
Current Clamp
2PCS :1 blue-black plug and 1 red-black plug
Clamp Caliber
Φ68mm
Clamp Turn Ratio
1000:1
Clamp Lead Wire
2m
Measuring Rate
AC current: about 2 times/second
Earth Voltage: about 2 times/second
Earth resistance: about 7 seconds/time
Measuring Times
Over 5000 times (Short-circuit test, interval time should be at least 30seconds)
Line Voltage
Measurement below AC 600V
Communication Interface
USB interface, storage data can be uploaded to computer, saved or printed.
Communication Wire
USB communication wire x1pcs, with length 1.5m
Data Hold
Data hold function: “HOLD” symbol display
Data Storage
2000 groups, “MEM” storage indicator, “FULL” symbol flash display storage is full
Data Access
Data read function: “READ” symbol display
Overflow Display
Exceed measuring range overflow function: “OL” symbol display
Low Current Indicator of Current clamp
Measurement with select method or double clamp , the current signal received by CT2 is lower than 0.5mA, will display“ “, and should check the clamping direction of the CT2 current clamp
Interference Test
Automatic identification of interference signals, “NOISE” symbol indication when the interference voltage is higher than 5V
Auxiliary Grounding Test
With auxiliary grounding resistance test function, 0.00KΩ-30kΩ(100R+rC<50kΩ, 100R+rP<50kΩ)
Alarm Function
Measurement value exceeds alarm setting value, will "Toot-toot-toot" alarm hint
Battery Voltage
While battery voltage decreases to around 7.2V±0.1V, will display battery voltage low symbol“ ”, and reminding to replace the battery
Auto-shut off
Automatically shut down after 15 minutes of power on
Power Consumption
Backlight: 25mA Max(only backlight power consumption)
Standby:25mA Max(Backlight off after power on)
Measurement:150mA Max(Backlight shut off)
Weight
Tester: 2.23kg
Tester package: 0.915kg
Current Clamp:1.05kg(2pcs)
Test wires: 1.56kg(include the simple test wires)
Auxiliary grounding rods: 0.935kg(4pcs)
Working Temperature & Humidity
-10
℃
-40
℃
, below 80%rh
Storage temperature & humidity
-20
℃
-60
℃
, below 70%rh
Protection Level
IP65(close the case)
Overload Protection
Measure earth resistance: between each interfaces of C(H)-E
、
P(S)-ES,AC 280V/3 seconds
Insulation Resistance
Over 20MΩ(between circuit and outside shell is 500V)
Withstanding Voltage
AC 3700V/rms. (Between circuit and outside shell)
Electromagnetic Features
IEC61326(EMC)
Protection Type
IEC61010-1(CAT
Ⅲ
300V
、
CAT IV 150V
、
Pollution 2);
IEC61010-031;
IEC61557-1(Earth resistance);
IEC61557-5(Soil resistivity);
JJG 366-2004(Grounding resistance meter)
JJG 1054-2009(Clamp grounding resistance meter)
Packing :
Meter
1 PCS
Meter Bag
1 PCS
Auxiliary Grounding Rod
4 PCS
Test Wires
4PCS (Red 20m; Yellow: 10m; Green: 10m; Black:20m)
Simple Test Wires
2 PCS (Red 1.6m; Black 1.6m)
Current Clamp
2 PCS
Monitoring sortware CD
1 COPY
USB Communication Cable
1 PCS
Special Charger
1 PCS
Manul/Warranty Card/Certificate
1 SET