-40%

Clamp on Earth Resistance Meter Tester 0.01-1200Ω Leakage Current Detector 20A

$ 194.83

Availability: 100 in stock
  • Tester Weight: 1160g
  • Ground Resistance Range: 0.010Ω~1200Ω
  • External Magnetic Field: <40A/m
  • Tester Dimension: 285mm×85mm×56mm
  • Restocking Fee: No
  • Brand: VTSYIQI
  • Alarm Threshold Setting Range: Resistance:1~199Ω
  • Features: Clamp
  • Item must be returned within: 30 Days
  • Return shipping will be paid by: Buyer
  • Clamp Size: 65mm×32mm
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money back or replacement (buyer's choice)
  • MPN: 2020369841
  • Warranty: 1 year
  • Country/Region of Manufacture: China
  • Single Measurement Time: 0.5 second
  • Ground Resistance Resolution: 0.001Ω
  • LCD Size: 4 Digits LCD display, Screen: 47mm×28.5mm
  • Condition: New
  • Data Storage: 99 sets
  • Current Range: 0.00mA~20.0A

    Description

    Clamp on Earth Resistance Meter Tester 0.01-1200Ω Leakage Current Detector 20A
    Instruction:
    ETCR2000C+ series clamp grounding resistance tester is our company's technology research and development team on technical quality of the pursuit of excellence, through continuous innovation to improve, upgrade with the old product. Its performance is mainly reflected in:
    Breakthrough in self-test the boot a long time to waiting, start immediately into the test. Breakthrough relay self-test mode, using the most advanced processing algorithms and digital integration technology. Breakthrough the old product to heavy issues, more in line with characteristics of hand-held devices.New design, panel operation with 6 buttons, better performance. Increase sound and light alarm function, with "beep-beep-beep” alarm sound. Increase the interference signal recognition indicator function, with "beep-beep-beep” indicator.Measurement resistance range: 0.01Ω-1200Ω and current range :0.00mA~20.0A .Stored data 99 Units. Lower power consumption, Maximum operating current less than 50mA.
    ETCR2000C+ series Clamp Grounding Resistance Tester is widely used in the grounding resistance measurement of the power, telecommunications, meteorology, oilfield, construction and the industrial and electrical equipment. In the measurement of a grounding system with loop, does not require breaking down the grounding down lead, and no need the auxiliary electrode. It is safe, fast and simple in use. The tester can measure ground faults which cannot be measured by traditional methods. It can be used in applications where traditional methods cannot be measured, because the ETCR series clamp grounding resistance meter measures the combined value of grounding body resistance and grounding lead resistance.
    Product Main Function
    1. Measurement of earth resistance,loop resistance
    2. Resistance Measure Range: 0.010Ω~1200Ω
    3. Leakage Current Measure Range: 0.00mA~20.0A
    4. Alarm Threshold Setting

    1-199Ω
    5. Alarm Function: audible and visible alarm
    6. CT Size: 65mmX32mm
    Specification:
    Power Supply
    6VDC 4 PCS of LR6 lkaline batteries
    (not included)
    Clamp Size
    65mm×32mm
    LCD Size
    4 Digits LCD display, Screen: 47mm×28.5mm
    Range
    Resistance: 0.010Ω~1200Ω
    Current: 0.00mA~20.0A
    Resolution
    Resistance: 0.001Ω; Current: 0.05mA
    Accuracy
    Resistance: ±1%±0.01Ω; Current:±2.5%±1mA
    Data Storage
    99 sets
    Data Upload Function
    RS232 Interface (Optional)
    Auto Power-off
    Automatically power off after 5 minutes without any operate
    Power Consumption
    ≤50mA

    continuously working for 30 hours
    Working Environment
    -20

    ~55
    ℃;
    20%rh~80%rh
    Store Environment
    -20

    ~60
    ℃;
    below 90%rh
    Alarm Threshold Setting Range
    Resistance

    1~199Ω
    Audible and VisibleAlarm
    “Beep-beep-beep” alarm sound, alarm symbol flashing, pressALkey to turn  on/off and setting
    Interference Signal Recognition
    “Beep-beep-beep” indicator,NOISEsymbol blinking
    Protection Level
    Double insulation
    Structural Feature
    Clamp CT
    Shift
    Automatic shift
    External Magnetic Field

    40A/m
    External Electrical Field

    1V/m
    Single Measurement Time
    0.5 second
    Resistance Measurement Frequency

    1KHz
    Measured Current Frequency
    50/60Hz Automatic
    Low Battery Voltage Indication
    When the battery voltage is lower than 5.3V, the low battery voltage symbol is displayed
    Storage Full Indication
    Storage data full of 99 sets,flashed display "MEM" symbol
    Over Range Indication
    Over range indication “OLΩ”, “L0.01” or “OL A”
    Tester Weight
    1160g
    Tester Dimension
    285mm×85mm×56mm