-40%

Clamp Ground Earth Resistance Meter Tester 1200ohm Current Tester 40A RS232

$ 290.34

Availability: 100 in stock
  • All returns accepted: Returns Accepted
  • Return shipping will be paid by: Buyer
  • Country/Region of Manufacture: China
  • Current Resolution:: 0.05mA
  • Current Range:: 0.00mA-40.0A
  • Brand: VTSYIQI
  • Restocking Fee: No
  • Clamp Opening Extent:: 32mm
  • MPN: 20200104
  • Data memory:: 99 Sets
  • Item must be returned within: 30 Days
  • Features: Clamp
  • Resistance Resolution:: 0.001Ω
  • Resistance Range:: 0.01-1200Ω
  • Condition: New
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    Clamp Ground Earth Resistance Meter Tester 1200ohm Current Tester 40A RS232
    Introduction:
    multi-functional clamp ground resistance tester, grounding resistance and loop resistance measurement (range: 0.010Ω ~ 1200Ω); leakage current measurement (range: 0.00mA ~ 40.0A). When measuring the looped grounding system, it is not necessary to disconnect the ground deflector and no auxiliary electrode is needed. Just clamp the meter and clamp it directly on the ground lead. The value displayed by the clamp meter is the grounding body resistance and The integrated value of the ground lead resistance, this measurement method can quickly and safely obtain the measurement results.
    Specifications:
    Function:Ground resistance test, Loop resistance test
    Resistance Range:0.01-1200Ω
    Resistance Resolution:0.001Ω
    Highest Resistance Accuracy:±1%±0.01Ω
    Current Range:0.00mA-40.0A
    Current Resolution:0.05mA
    Highest Current Accuracy:±2.5%±1mA
    Data memory:99 Sets
    Alarm Threshold Setting Range: 1-199Ω
    Clamp Size:Φ32mm
    Clamp Opening Extent:32mm
    Clamp Dimension:L×W×T: 285mm×85mm×56mm
    Protection Level:Dual Insulation
    Structural Feature:Clamp CT
    Shifting:Automatic shifting
    External magnetic field:<40A/m
    External electrical field:<1V/m
    Single measurement time:0.5 second
    Resistance measurement frequency:>1KHz
    Measured current frequency:50/60Hz Automatic measurement
    Low Battery Indication:Low battery symbol displays when battery is lower then 5.3V
    Memory Full Indication:MEM symbol blinks when all 99 sets memory is full
    Auto Power-off:5 minutes after Boot up
    RS232 Interface :The data stored in the meter are uploaded to the computer through RS232 interface and data wire, Then generate report files
    (1)
    . Alarm Symbol
    (2)
    . Symbol of low battery & voltage
    (3)
    . Symbol of full data storage
    (4)
    . Symbol of data access
    (5)
    . 2-Digital No. Of Data Storage Unit
    (6)
    .
    Current unit
    (7)
    . Resistance unit
    (8)
    . Noise signal
    (9)
    . Data lock symbol
    (10)
    .Symbol of an open jaw
    (11)
    . Symbol of DC
    (12)
    . Metrication decimal point
    (13)
    . 4-digital LCD figures display
    (14)
    . Symbol of AC