-40%

Built in Grounding Resistance Tester Online Earth Resistance Detector 0.010~200Ω

$ 104.54

Availability: 100 in stock
  • Ground Resistance Resolution: 0.001Ω
  • Country/Region of Manufacture: China
  • Restocking Fee: No
  • Shift: Automatic shift
  • MPN: 68978
  • Current Range: /
  • Sensor Weight: 680g;
  • Condition: New
  • PCB Size: 122mm×56mm×20mm
  • Ground Resistance Range: 0.010Ω~200Ω
  • Working current: 50mA Max.
  • Item must be returned within: 30 Days
  • External Magnetic Field: <40A/m
  • External Electric Field: <1V/m
  • Return shipping will be paid by: Buyer
  • Brand: VTSYIQI
  • Accuracy: ±2%rdg±3dgt(20℃±5℃,below 70%RH
  • All returns accepted: Returns Accepted
  • Refund will be given as: Money back or replacement (buyer's choice)

    Description

    Built in Grounding Resistance Tester Online Earth Resistance Detector 0.010~200Ω
    Instruction:
    ETCR2800 Non-contact Earth Resistance On-line Monitor is high-tech product that our company has devoted to "grounding resistance detection technology research" for more than ten years, specialize for online monitoring grounding down lead connection status, circuit grounding resistance and metal circuit connection resistance range: 0.010Ω~200Ω. On-line testing, non-contact measurement, grounding wire pass through the perforation of the detector, definitely will not influence grounding effective for lightening and normal operation, no need the self-inspection, real time on-line testing. Provide RS485 wire communication (support MODBUS-RTU communication protocol) or GPRS wireless communication data transmission, The monitor is composed of sensor and PCB module, which is suitable for user secondary development integration.
    ETCR2800 Non-contact Earth Resistance On-line Monitor can install and use singly, and also can set up wired or wireless network system.
    Product Main Function
    1. On - line monitoring the earth resistance of grounding system
    2. Measure Range: 0.010Ω~200Ω
    3. Equip with RS485( support MODBUS-RTU communication protocol) or GPRS interface
    4. can be built into inside case  of other equipment ,convenient the secondary development and integration by users
    5. Network system can be built to realize real-time detection and remote monitoring
    Specification:
    Function
    Loop circuit grounding resistance on-line monitoring, metal return circuit resistance connection online monitoring, grounding condition monitoring. anti-theft monitoring of grounding wires and metal cables
    Power Supply
    Detector

    6VDC

    9VDC

    50mA Max(external power supply).
    Resistance  Range
    0.01Ω~200Ω
    Resolution
    0.001Ω
    Accuracy
    ±2%rdg±3dgt(20

    ±5
    ℃,
    below 70%RH)
    PCB Size
    122mm×56mm×20mm
    Sensor Size
    ETCR2800N

    110mm×80mm×55mm
    Sensor Perforation Size
    ETCR2800N

    65mm×36mm
    Sensor Weight
    ETCR2800N

    680g

    Overflow Indication
    Test data>200Ω, communication send “OLΩ” command
    PCB Interface
    J1

    Signal output, power input interface
    J2

    Sensor and PCB interface
    Symbol J1
    P+:Power input with positive R+

    Signal output with positive
    P-

    Power input ground     R-: Signal output with negative
    GND

    Signal ground, short connect with power input ground (P-)
    Symbol J2
    I+

    I-Current coil interface U+

    U-Voltage coil interface
    GND

    Common ground
    Connect Wire
    1pcs ,1 meter length(5 core wire)
    Connection Identifier
    Red/brown---power supply input anode;
    Black--- power supply input cathode;
    Blue---RS485 signal anode;
    Grey---RS485 signal cathode;
    White--- grounding wire shield
    (power supply input cathode can connects with analog grounding by short circuit connection)
    Communication method
    RS485 communication protocol(support MODBUS)
    GPRS communication (optional)
    Working Temperature And Humidity
    -20

    ~55

    ; 20%RH~90%RH
    Shift
    Automatic shift
    Grounding lead Interference Current
    Should be avoid
    External Magnetic Field
    <40A/m
    External Electric Field
    <1V/m
    Single Measurement time
    About 0.5 second
    Working current
    50mA Max.
    Installation
    The ground wire goes through the center hole of the sensor
    Installation Demand
    PCB should install into other protective case
    Packing :
    Package
    Outer package
    Carton
    Inner package
    None
    Accessory
    Meter
    1 pcs
    Power and Communication Cable
    1 pcs
    PCB module
    1 pcs
    Certificate
    1 pcs
    Manual
    1pcs
    Warranty Card
    1 pcs